Skip to content
Sector · PET Bottle Blowing

Compressed Air for PET Bottle Blowing

High-pressure air for PET blow moulding: two-stage screws at 18–30 bar, piston compressors at 30 or 40 bar, WH boosters to 40 bar, and dryers and filters rated for the pressure.

Overview

What this sector asks of its compressors

A PET bottling plant runs two air systems. The blow-moulder needs high-pressure air to form each bottle; the filling line, capping and plant utilities run on ordinary low-pressure air. Lighter water bottles have brought final blow pressure toward 20–25 bar. The blow-moulder's data sheet sets the pressure and flow, and the bottler's food-safety plan sets the air class.

EMAX offers three ways to make blow air. The TSC-PV two-stage screw reaches 18–30 bar on one machine, from 15 to 480 HP, with permanent-magnet variable speed across the range. The PET series two-stage piston takes atmospheric air to 30 or 40 bar, 11–22 kW, with no upstream compressor. Where a plant already runs screw air at around 10 bar, a WH booster raises it to 25, 30 or 40 bar, 2.0–16.0 m³/min.

High-pressure air needs treatment rated for the pressure. ADH-H refrigerated dryers work at 20–40 bar, 1.2–45 m³/min across twelve models. TRHF filters are rated to 40 bar, in C, T, A, X and H grades plus F dust filters. Blowing air touches the inside of the bottle, so put the dryer and filters on the same order and confirm the compressor configuration and filter grades with EMAX engineering against the bottler's air class.

The rest of the plant runs on low-pressure air. The PM VSD cabinet screw, 5.5–100 HP at 10 bar, follows the filling line's demand; EMAX's own testing puts its electricity saving at 30–60 % against an equivalent fixed-speed unit, depending on workload. Where a WH booster is used, the same screw supply feeds both the filling line and the booster.

Applications

Where this fits in the field

  • Water and soft-drink bottling · PET blow moulding at 18–40 bar
  • New lines · one two-stage screw from 18 to 30 bar (TSC-PV)
  • Single blow-moulders · 30 or 40 bar from one piston machine (PET series)
  • Retrofits · blow pressure added on top of an existing 10 bar screw supply (WH booster)
  • High-pressure drying and filtration · ADH-H dryers and TRHF 40 bar filters
  • Filling, capping and conveying · low-pressure plant air (PM VSD)
Specifier's guide · 01 / 03

Choosing the high-pressure source

One machine to blow pressureTSC-PV two-stage PM VSD screw15–480 HP · 18–30 bar · 20 model sizes, 82 configurations · air-cooled below 60 HP, water cooling available from 60 HPA new line, or one variable-speed source in place of several machines
Atmospheric air to 30 or 40 barPET series two-stage piston11–22 kW (15–30 HP) · 1.0–2.0 m³/min · 30 or 40 bar · 400 V three-phaseA single blow-moulder, with no separate low-pressure compressor needed
Boost existing screw airWH booster25 / 30 / 40 bar · 2.0–16.0 m³/min · 24 configurations · air- or water-cooled, single or twinThe plant already runs screw air at around 10 bar with flow to spare for the booster

Pressures offered vary by model; see each series' model table. EMAX engineering confirms the selection against the blow-moulder's data sheet.

Specifier's guide · 02 / 03

The high-pressure treatment train

Refrigerated drying at pressureADH-H high-pressure refrigerated dryer20–40 bar · 1.2–45 m³/min · 12 models · maximum inlet temperature 65 °C · 220 V / 50 Hz (ADH-10-H to ADH-120-H), 380 V / 50 Hz (ADH-150-H to ADH-400-H)
Particle and oil filtrationTRHF high-pressure filter40 bar maximum working pressure · 1.2–13 m³/min per housing · 7 models · carbon steel housing · up to 80 °C
Filter element gradesTRHF C · T · A · X · H · FC 3 µm / 3 ppm · T 1 µm / 1 ppm · A 0.01 µm / 0.01 ppm · X 0.01 µm / 0.003 ppm · H activated carbon 0.01 µm / 0.001 ppm · F dust 0.1 µm

ADH-H is rated from 20 bar, so an 18 bar TSC-PV duty is sized by EMAX engineering, as are flows above a single TRHF housing. Filtration grade and housing pressure are separate selections. The figures above are product ratings, not ISO 8573-1 class claims: the bottler's plan sets the class, and EMAX engineering confirms the whole train against it.

Specifier's guide · 03 / 03

What to send with the enquiry

Blow-moulder make, model and data sheetSets the pressure and flow the system is sized to
Final blow pressure and air consumptionDecides between the TSC-PV, PET series and WH booster routes
Existing low-pressure supply: pressure, spare flow and air treatmentDecides whether a WH booster can run on it
Air class in the bottler's food-safety planSets the dryer and filter grades
Cooling water on siteWater-cooled TSC-PV builds (60 HP and up) and water-cooled WHS boosters need it
Supply voltage and frequencyThe PET series is 400 V three-phase; ADH-H runs on 220 V or 380 V by size

The EU Declaration of Conformity and the pressure-vessel documents for your market are supplied on request for the configuration quoted. MOQ, container mix and lead time are quoted per order.

Building a PET Bottle Blowing range for your market?

Send us the application, the market and the models you are considering. We reply within two business days.